Aitoly Instruments Co., Ltd
Soap Film Gas Flow Standard Device
Hotline:

+86) 0512-85162266

Product Overview

The ESMFM-610 soap film gas flow standard device adopts high-sensitivity infrared photoelectric tube sampling, precision circuit control, microcomputer processing, touch screen control and display, and multi-channel measurement. It has intuitive display, convenient operation, accurate data, a large measurement range, and can save up to 10W of black history measurement data. This instrument is widely used for the measurement of small gas flow and the detection of leakage rate. The high-configuration model has a built-in 4-channel high-precision, high-control stability gas mass flow controller (MFC), which provides high-precision and high-stability gas output for measurement, making the measurement more accurate and convenient.

Features

Multi-channel measurement:The appropriate measurement channel can be selected according to different measurement ranges, which greatly improves the measurement range and measurement accuracy of gas flow, and the measurement channel switching is simple.

Accurate sampling: High-speed, high-sensitivity infrared sensor sampling, high-computing power chip control timing, so that the sampling time is accurate, thereby avoiding errors caused by manual readings, greatly improving the overall accuracy of the instrument.

Real-time temperature, pressure measurement and conversion: High-precision temperature and pressure sensors measure the temperature and pressure of the gas to be measured in real time and accurately, and convert the measured working flow into the required standard flow value synchronously.

Intelligent processing and control: Automatically identify the measurement channel, each channel independently displays the standard flow value, and the standard temperature is optional; automatic statistical processing and recording of measurement data (average value, RSD)

Built-in 4-channel MFC gas mass flow controller, control stable airflow for high-precision gas flow measurement, making the measurement more accurate and convenient.

Large screen display, simple and convenient operation.

Application Scenario

Gas sampler flow calibration

Flue monitoring instrument flow calibration

Laboratory analysis instrument carrier gas flow calibration

Test instrument gas flow calibration

Gas flow meter calibration

Workpiece leakage rate detection

Technical Parameters
Sensor and Control Performance

Measuring flow range
    Channel 1:0.05~30 mL/min
    Channel 2:20~1000 mL/min
    Channel 3:600~6000mL/min

Measuring flow accuracy level     Level 0.5

4-way mass flow controller range and accuracy (optional)
   Gas path 1: Range 50sccm, Accuracy: 0.01sccm
   Gas path 2: Range 300sccm, Accuracy: 0.1sccm
   Gas path 3: Range 1000sccm, Accuracy: 0.1sccm
   Gas path 4: Range 6000sccm, Accuracy: 1sccm

Ambient temperature     Level 0.5

Relative humidity     85%

Power supply     220VAC

Applicable environment     Non-explosion-proof places

Copyright © Aitoly Instruments Co., Ltd All rights reserved Web design Registration Number:SuICP No. 2024140646-1